Wiring An Outdoor AC Unit

3 years ago
129

Electric Pro Academy - Real skills to make real money.

Synopsis:
Utility equipment may seem like a daunting DIY task, but with the exception of larger wire gauge, wiring an outdoor AC unit is little different than wiring a light switch. Mounting the components will differ from case-to-case, but in this video Joel will demonstrate how to mount an AC disconnect to brick, run THHN wire through PVC liquid-tight conduit, and make all the necessary electrical connections. Along the way he’ll make recommendations and point out professional details employed daily by Jefferson Electric masters, journeymen, & apprentices that give lifelong certainty to the integrity of the job.

If the instruction in this video is unclear or skew to what you are searching for, feel free to comment below for additional assistance. Got a question or ideas for a future video? Leave a comment below and submit your idea here: https://forms.clickup.com/f/23xa9-70/MU8E4HBGPNY3NXVQA3

Thank you for watching; we value your feedback and monitor this channel daily.

Products We’d Recommend:
*EPRO endorses pro-level tools & materials, and receives a small commission for purchases through our links through Amazon & other affiliate programs. We’d be happy to recommend more cost-effective products for DIYers and low-frequency users if you engage with us in the comment section!
[] Siemens 60A 240V General Duty Outdoor Non-Fusible Safety Switch: https://amzn.to/3f6qDAx
[] Klein Tools 7/8 - 1-3/8 in. Step Drill Bit: https://amzn.to/32Iy0eT
[] Dewalt 20 Max VR Brushless Hammer Drill (DCD999B): https://amzn.to/3mVpkbP
[] Fluke 117 Multimeter: https://amzn.to/3HDFZJ0
[] 3/16" x 1-1/4" Tapcons: https://amzn.to/3mWmjIf
[] Dewalt 20V Max XR SDS-Plus Rotary Hammer (DCH263): https://amzn.to/3foIwdD
[] Swanson Magnetic Level: https://amzn.to/3GaN0Rf
[] iDEAL NOALOX Anti-Oxidant Compound: https://www.homedepot.com/p/NOALOX-4-oz-Anti-Oxidant-Compound-30-026/202276208
[] Gardner Bender Duct Seal: https://www.homedepot.com/p/Gardner-Bender-1-lb-Plug-Duct-Seal-Compound-DS-110/100212441
[] OSI Quad Clear Caulk: https://www.homedepot.com/p/OSI-Quad-Advanced-Formula-10-fl-oz-Clear-000-Exterior-Window-Door-and-Siding-Multi-Purpose-Sealant-2097583/206284062
[] ATG Maxiflex Nitrile Gloves: https://www.homedepot.com/p/ATG-MaxiFlex-Men-s-Large-Nitrile-Ultimate-Gloves-in-Gray-34-874T-LVPD72/313135021
[] Assorted THHN Wire: https://www.homedepot.com/b/Electrical-Wire-Building-Wires/THHN/N-5yc1vZc57aZ1z0zuec

National Electrical Code (NEC) referenced in this video:
Free Access Here: https://www.nfpa.org/codes-and-standards/all-codes-and-standards/list-of-codes-and-standards/detail?code=70
[] Disconnection of Permanently Connected Appliances [NEC 422.31]

Outline:
0:00 - Introduction
0:37 - Pre-Removal Check-Up
1:03 - Check For Power
3:15 - Shut Off Power
4:02 - Remove Old Disconnect
6:32 - Prep New Disconnect
14:45 - Pre-Drill Mounting Holes
18:30 - Pre-Mount Waterproofing
21:30 - Pigtail Short Wires From Panel (Line Side)
27:04 - Mount New Disconnect
28:24 - Wire Panel-to-Disconnect (Line Side)
32:15 - Remove Disconnect-to-AC Unit (Load Side) conduit
34:40 - Connect New Load Side Conduit
40:20 - Wire Load Side Disconnect
47:14 - Anchor Conduit
49:20 - Wire AC Unit
52:57 - Torque & Test Disconnect

Connect With Us:
Jefferson Electric services residential, commercial, solar, and Tesla systems in Indianapolis, IN.
https://www.jeffersonelectricllc.com/
https://www.facebook.com/JeffersonElectric
https://www.linkedin.com/company/jefferson-electric-llc/

Loading 1 comment...